Voltage: 0-5 V DC or 0-10 V DC output, linear with measured temperature, rescalable, configurable via NFC
or
Type K Thermocouple output
Alarm Output
Open collector alarm output with temperature threshold and hysteresis, configurable via NFC
Note: Alarm and temperature outputs may be used simultaneously
Field of View
15:1 (see Field of View Diagram)
Accuracy
± 1.5% of reading or ± 1.5°C, whichever is greater
Repeatability
± 0.5% of reading or ± 0.5°C, whichever is greater
Response Time
125 ms (90% response)
Configuration
Via Android app using NFC-equipped device (e.g. smartphone or tablet)
Emissivity
Adjustable via app
Emissivity Setting Range
0.2 to 1.0
Max Temperature Span (Voltage Output)
1000°C
Min Temperature Span (Voltage Output)
100°C
Spectral Range
8-14 μm
Max. Supply Voltage
28 V DC
Min. Supply Voltage (at Sensor)
12 V DC (for 10 V output) 6 V DC (for 5 V output)
Max Current Draw
6 mA
Smartphone Configurable Infrared Temperature Sensor
Temperature range 0°C to 1000°C
Non-contact industrial temperature sensor
Fully configurable via smartphone app
Choice of voltage or thermocouple outputs
Alarm output on all models
Extremely small, with side-entry cable: ideal for mounting in tight spaces
Form factor optimised for brake testing applications, plus many others
System Requirements
Android 4.1 to 5.1 NFC (to check if your phone has NFC, visit www.nfcworld.com/nfc-phones-list )
Note: Not yet compatible with iPhone because NFC functionality has not yet been made available by Apple.
Configurable Parameters
Temperature range (models with voltage output only) Linear voltage output type and scale (models with voltage output only) Alarm output threshold and hysteresis Emissivity setting Reflected temperature
Temperature Units
°C / °F
Signal Processing
Averaging Period (0.125 to 60 seconds) Peak / Valley Hold Hold Period (0.125 to 120 seconds)
Real Time Temperature Reading
Hold NFC device against sensor for continuous in-app temperature updates